Guidelines for communications infrastructure
53 controls in 2 sections in this part of the ASD ISM. Each control links to plain-English guidance, audit tips and cross-framework mappings.
53 controls
No controls on this page match.
Cabling infrastructure
47 controls- ISM-0181Ensure cabling meets Australian StandardsInstall cabling infrastructure to the relevant Australian Standards as the Australian Communications and Media Authority directs, which currently include the Wiring Rules for customer cabling.NCOSPSTS
- ISM-0187Exclusive SECRET cable bundling in infrastructureWhen SECRET cables are bundled together or run in conduit, that bundle or conduit must carry SECRET cables only, with no other cable in it.S
- ISM-0194Sealing conduit joints in shared facilitiesOn TOP SECRET systems in shared facilities, seal all plastic conduit joints, and conduits connected by threaded lock nuts, using conduit glue applied as a visible smear.TS
- ISM-0195Seal removable covers on TOP SECRET cablesIn shared facilities, every removable cover on TOP SECRET cable reticulation systems must carry a uniquely identifiable, SCEC-approved tamper-evident seal.TS
- ISM-0198Consultation for penetrating audio secure roomsAny penetration of a TOP SECRET audio secure room requires consulting the Australian Security Intelligence Organisation and complying with all the directions it provides.TS
- ISM-0201Labelling requirements for TOP SECRET conduitsLabel TOP SECRET conduits at five-metre intervals, using labels of at least 2.5 cm x 1 cm marked 'TS RUN'.TS
- ISM-0206Develop and maintain cable labelling processesCable labelling processes, and the procedures that support them, must be developed, put into use and kept up to date.NCOSPSTS
- ISM-0208Record the required details for each cable in the cable registerThe cable register must record each cable's identifier, colour, sensitivity/classification, source, destination and location, plus seal numbers where they apply.NCOSPSTS
- ISM-0211Develop and verify a cable registerCreate a cable register, use it, keep it up to date and regularly check it against the cabling itself, at a period the organisation sets because the control names none.NCOSPSTS
- ISM-0213Individual patch panels for SECRET and TOP SECRET cablesSECRET cables and TOP SECRET cables must each terminate on their own individual patch panels, so no panel mixes them with each other or with any other cables.STS
- ISM-0216Ensure separate cabinets for TOP SECRET patch panelsTOP SECRET patch panels must be installed in individual TOP SECRET cabinets; a non-TOP SECRET panel may share only where spatial constraints demand it and ISM-0217's conditions are met.TS
- ISM-0217Secure separation of non-TOP SECRET and TOP SECRET panelsA non-TOP SECRET patch panel may share a TOP SECRET cabinet only where space demands it, with a physical barrier, Positive Vetting access only and the authorising officer's prior approval.TS
- ISM-0218Label and protect long TS fibre-optic leadsTOP SECRET fibre-optic fly leads over five metres must run in a protective, easily inspected pathway, labelled at the IT equipment end with the wall outlet box's identifier.TS
- ISM-0926Cables below SECRET must not be salmon pink or redNon-classified, OFFICIAL: Sensitive and PROTECTED cables must not be salmon pink or red, the colours set for SECRET and TOP SECRET cables.NCOSP
- ISM-1095Proper labelling of wall outlet boxesEach wall outlet box must show three things: the systems it serves, the identifiers of its cables and its own box identifier.NCOSPSTS
- ISM-1096Ensure proper labelling of cables for identificationLabel each cable at both ends with enough source and destination details that someone can physically identify and inspect it.NCOSPSTS
- ISM-1098Segregate SECRET cable terminations using individual cabinets or division platesSECRET cables must terminate in an individual cabinet; only a small system may instead use a cabinet with a division plate between SECRET cables and any non-SECRET cables.S
- ISM-1100Terminating TOP SECRET cables in cabinetsTOP SECRET cables must terminate in an individual TOP SECRET cabinet, one kept for TOP SECRET, and the small-system division plate option in ISM-1098 does not apply.TS
- ISM-1101Terminate cabling closely in TOP SECRET areasIn TOP SECRET areas, cable reticulation systems must end as close as possible to cabinets in server or communications rooms; cabinets outside those rooms fall under ISM-1103.NCOSPSTS
- ISM-1102Terminate cable reticulation close to cabinetCable reticulation systems such as trays and ducts must end as close as possible to any cabinet they lead into; no distance is set, so it depends on what the site physically allows.NCOSPSTS
- ISM-1103Terminate TOP SECRET area cable reticulation at the cabinet boundaryIn TOP SECRET areas, cable reticulation systems leading into cabinets outside server or communications rooms must end at the cabinet's boundary, with no stretch of cable between them.NCOSPSTS
- ISM-1105Ensure wall outlets have appropriate cable securityA SECRET or TOP SECRET wall outlet box must hold only SECRET or TOP SECRET cables, with no cable of any other classification.STS
- ISM-1107Colour restrictions for wall outlet boxesNon-classified, OFFICIAL: Sensitive and PROTECTED wall outlet boxes must not be salmon pink or red, the colours set for SECRET and TOP SECRET boxes.NCOSP
- ISM-1109Ensure clear plastic covers for wall outletsEvery wall outlet box cover must be clear plastic, so the connections inside can be seen without opening the box.NCOSPSTS
- ISM-1111Ensure fibre-optic cables replace copper cablesUse fibre-optic cables rather than copper cables for cabling infrastructure; no exceptions are listed, so copper still in use is a shortfall until replaced.NCOSPSTS
- ISM-1112Ensure cables in non-TOP SECRET areas are inspectable every five metres or lessCables in non-TOP SECRET areas must be inspectable at points no more than five metres apart, so no stretch longer than that is out of reach.NCOSPS
- ISM-1114Ensure separation in cable reticulation systemsCable bundles or conduits sharing a cable reticulation system must each be separated from the next by a dividing partition or a visible gap.NCOSPSTS
- ISM-1115Ensure cables use conduits in wallsEvery cable from a cable tray to a wall outlet box must run in conduit that is flexible or plastic, with no bare stretch.NCOSPSTS
- ISM-1116Ensure separation between TOP SECRET and other cabinetsTOP SECRET cabinets and non-TOP SECRET cabinets must have a visible gap between them; cabinets that touch, are bolted together or have the gap filled do not meet this, and no width is set.TS
- ISM-1119Ensure cables in TOP SECRET areas are inspectableCables in TOP SECRET areas must be fully inspectable along their entire length, leaving no stretch of any length that cannot be examined.NCOSPSTS
- ISM-1122Secure TOP SECRET cable wall exitsWhere a wall penetration exits a TOP SECRET area into a lower classified area, encase TOP SECRET cables in conduit and fill all gaps around it with an appropriate sealing compound.TS
- ISM-1123Ensure UPS powers all TOP SECRET IT equipmentPower all TOP SECRET IT equipment from a power distribution board that has a feed from an Uninterruptible Power Supply (UPS), not only the servers or other critical items.TS
- ISM-1130Use enclosed systems for shared facility cablesIn shared facilities, cables must run inside an enclosed cable reticulation system, not on open trays or loose in ceiling or floor spaces.NCOSPSTS
- ISM-1133Prevent installation of TOP SECRET cables in shared wallsIn shared facilities, keep TOP SECRET cables out of party walls, the walls dividing your space from another occupant's.TS
- ISM-1164Use clear plastic for shared facility cabling coversIn shared facilities, conduits and the front covers of ducts and of cable trays in floors and ceilings must be clear plastic, as must associated fittings.NCOSPSTS
- ISM-1216Ensure correct labelling of non-conformant cablesSECRET and TOP SECRET cables not in their required colour must be banded with the appropriate colour and labelled at inspection points.STS
- ISM-1639Label building management cables clearlyGive building management cables yellow labels with black writing stating their purpose, each at least 2.5 cm x 1 cm and attached at five-metre intervals.NCOSPSTS
- ISM-1640Label cables for foreign systems in AustraliaCables for foreign systems installed in Australian facilities must carry a label at each inspection point, so they can be told apart from Australian systems' cables.NCOSPSTS
- ISM-1645Maintain and verify floor plan diagramsDraw floor plan diagrams of the cabling infrastructure, use them, keep them up to date and regularly check them against the site, at a period the organisation sets.NCOSPSTS
- ISM-1646Detail cabling paths and points on floor plansFloor plan diagrams must show all cable paths, including where cables cross between floors, reticulation and conduit routes, floor concentration boxes, wall outlet boxes and network cabinets.NCOSPSTS
- ISM-1718Colour code for SECRET cablesSECRET cables must be coloured salmon pink; a SECRET cable in any other colour must be banded and labelled under ISM-1216 but does not meet this control until replaced.S
- ISM-1719Colour code for TOP SECRET cablesTOP SECRET cables must be coloured red; a TOP SECRET cable in any other colour must be banded and labelled under ISM-1216 but does not meet this control until replaced.TS
- ISM-1720Colour coding for SECRET wall outlet boxesEvery SECRET wall outlet box must be salmon pink, not just labelled or marked as SECRET.S
- ISM-1721Red colour coding for TOP SECRET outlet boxesEvery TOP SECRET wall outlet box must be red, not just labelled or marked as TOP SECRET.TS
- ISM-1820Ensure consistent cable colours for systemsAll the cables for any one system must use the same colour, whatever the cable type; the control does not require each system to have a different colour.NCOSPSTS
- ISM-1821Ensuring exclusive bundling for TOP SECRET cablesWhen TOP SECRET cables are bundled together or run in conduit, that bundle or conduit must carry TOP SECRET cables only, with no other cable in it.TS
- ISM-1822Standardised colour for wall outlet boxesEach system's wall outlet boxes must all be one consistent colour, on every floor and site where that system runs.NCOSPSTS
Emanation security
6 controls- ISM-0246Seek emanation security risk assessments as early as possibleWhenever an emanation security risk assessment is required, seek it as early as possible in the system's life cycle, rather than once the design is settled.STS
- ISM-0249Contact ASD on emanation security for deployable SECRET and TOP SECRET systemsA system owner must contact ASD for an emanation security risk assessment when deploying a SECRET or TOP SECRET system in a mobile platform or as a deployable capability.STS
- ISM-0250Ensure IT equipment meets EMI/EMC standardsIT equipment must meet both industry and government standards on electromagnetic interference and electromagnetic compatibility, with no limit by classification.NCOSPSTS
- ISM-1137Request risk assessment for emanation securityA system owner must contact ASD for an emanation security risk assessment when deploying a SECRET or TOP SECRET system within a fixed facility.STS
- ISM-1884Ensure compliance with emanation security doctrineComply with the emanation security doctrine ASD produces for managing emanation security matters, which adds to the ISM's own controls and takes precedence where they conflict.OSPSTS
- ISM-1885Implement emanation security measures for systemsSystem owners must implement the recommended actions in emanation security mitigation advice issued for their systems; recommended does not mean optional, and holding the advice is not enough.STS
Back to the full Australian Government Information Security Manual control list, or browse the complete control library.